Hybrid solar and wind generation
From history to 30 years
The 2008–2017 hourly balance accounts for generation, loads, storage and grid limits. The annual average is projected over the financial horizon with degradation, prices, costs, taxes and discounting to calculate NPV. This is not a weather forecast.
03 Energy results
Wind results here precede the additional converter cap. The combined balance below applies it.
ERA5 describes timing; GWA calibrates the local mean. This comparison is not independent validation.
How we use ERA5 and Global Wind Atlas data
Detail by height
Monthly and annual tables
Sources and actual coordinates
Preliminary estimate with modeled data, not site measurements. Buildings, obstacles, turbulence and within-hour variability are not explicitly modeled.
Combined generation
Historical PVGIS-ERA5 and wind series are matched by UTC hour in 2008–2017. PV uses an exploratory isotropic model with temperature and clipping; direct normal irradiance is inferred from horizontal beam irradiance, limited near the horizon. This is not TMY.
Converter balance · annual mean
Potential outputs already include source losses, before the configured power caps. Clipping is unconverted energy, distinct from grid curtailment and battery losses. The PV chart represents standalone PV with the selected converter limit.
Monthly and annual tables
Official PVGIS reference
PVcalc: long-term climatology, not the historical hybrid balance; it does not use the inverter entered here.
Choose the PV optimization goal
Which tilt and azimuth work best? Compare 456 combinations (tilt 0–90° in 5° steps; azimuth 0–345° in 15° steps), holding power ratings, losses and other technical settings fixed.
The PV-only criterion assumes standalone PV with its own or shared limit and no competing wind. Hybrid criteria apply both sources hour by hour.
Original ERA5 uses meteorological model wind; GWA-calibrated ERA5 (if available) aligns local mean wind speed. Solar radiation remains PVGIS in both cases. The same UTC hours of 2008–2017 are compared.
04 Consumption, storage and economic assumptions
Configure shared parameters
For PV production alone, skip these settings. For combined energy, set loads, storage, grid and tariffs; for NPV, also enter investment and projections. The optimization and final evaluation share the same settings.
One load profile, storage system, export limit and tax model for both sources. Degradation is common to both generators, following the previous model convention.
One load profile, storage system, export limit and tax model for both sources. Degradation is common to both generators, following the previous model convention.
One battery charges from surplus PV + wind and discharges to loads or, if configured, for deferred sales. Capacity, power and efficiency limit energy shifted in time. It does not increase generation; it adds losses and costs.
The battery model is indicative: it does not reproduce cell chemistry, real control systems, temperature constraints or cycle aging. Future degradation is treated through simplified financial assumptions, not detailed physical lifetime modeling.
Investment and projections (required for NPV)
NPV is the present value of self-consumption savings and sales revenue, less costs, taxes and investment. Storage may increase savings but reduce sales and add costs. The best NPV orientation may differ from maximum PV production. Enter total plant costs excluding the separately specified battery.
Enter the total net cost and annual expenses for both systems (excluding battery).
Business costs and tax assumptions
Company tax estimates are deliberately simplified and do not separately calculate corporate taxes, statutory depreciation, financing, incentives or excise duties. Check the results with a qualified professional.
Hourly AC balance, 2008–2017. Load profiles use the configured 2025 calendar (29 February repeats 28 February). Charge carries across the decade; annual mean flows feed projections. As in PV, battery degradation reduces the extra economic benefit, not hourly capacity. No grid charging.
05 Run optimization
After selecting the goal and entering the required settings, calculate the map here. Skip this section to evaluate the current orientation. Select a cell and apply its angles to update production without downloading weather data again.
Rows: tilt from horizontal. Columns: azimuth (0° north, 90° east, 180° south, 270° west). Each cell shows the selected metric; select it to apply the angles. Darker blue means a higher value, not a profitability threshold. The optimum is limited to the grid.
06 Final economic evaluation (optional)
Calculate financial results for the active orientation, with and without storage if enabled. Applying an NPV-optimized orientation updates the results automatically. For financial comparison, complete investment and costs in section 04.
Annual cash flows at main height
Estimate limitations
Preliminary estimate with modeled data, not site measurements. Buildings, obstacles, turbulence and within-hour variability are not explicitly modeled.
Copernicus Climate Change Service (C3S) · ERA5 (2008–2017) · Global Wind Atlas 4.0 (DTU / World Bank / ESMAP) · Natural Earth.