EMPIREAHYBRID ENERGY SIMULATOR

Hybrid solar and wind generation

Data sources:Solar PV — PVGIS (JRC) supplies direct and diffuse horizontal solar irradiance and air temperature via PVGIS-ERA5. The model estimates plane-of-array irradiance, cell temperature, losses and conversion limits. Unlike the standalone PV simulator, it does not use a typical meteorological year (TMY).Common period — 1 January 2008 to 31 December 2017, including leap years: 87,672 UTC hours. Both sources are matched hour by hour to preserve simultaneity. Local civil time and historical daylight-saving rules align loads and tariffs without changing the weather timestamps.Wind — Copernicus/ECMWF ERA5 is a meteorological reanalysis combining historical observations with an atmospheric model, not direct turbine measurements at the site. Wind components at 10 and 100 m, temperature and pressure are used to estimate hub-height wind and output from the power curve, air density and losses. Global Wind Atlas can adjust the local mean wind speed; it is not a second observed hourly series.Common period — 1 January 2008 to 31 December 2017, including leap years: 87,672 UTC hours. Both sources are matched hour by hour to preserve simultaneity. Local civil time and historical daylight-saving rules align loads and tariffs without changing the weather timestamps.GWA 4.0 also uses ERA5 for 2008–2017, with finer-scale modelling of terrain and roughness. We extract the mean speed of the approximately 250 m cell at 10, 50 and 100 m, interpolating log speed in log height. We do not use a GWA hourly series or averages of the windiest areas.Common period — 1 January 2008 to 31 December 2017, including leap years: 87,672 UTC hours. Both sources are matched hour by hour to preserve simultaneity. Local civil time and historical daylight-saving rules align loads and tariffs without changing the weather timestamps.How we use ERA5 and Global Wind Atlas data

From history to 30 years

The 2008–2017 hourly balance accounts for generation, loads, storage and grid limits. The annual average is projected over the financial horizon with degradation, prices, costs, taxes and discounting to calculate NPV. This is not a weather forecast.

01 Location

The detailed map connects to OpenStreetMap, which receives your IP address and viewed areas. You can turn it off at any time.Drag the map or use the arrows to pan, zoom and click to select a site. Enter coordinates for precision.

Hybrid coverage only where both sources are available.

Common period 2008–2017 · hourly data (UTC).

02 Turbine and installation

Theoretical, uncertified parametric curve: cubic growth between cut-in and rated speed.

Height above ground, not sea level. Wind factor multiplies speed: 1 = no manual correction; it does not model obstacles.

Photovoltaic system

Conversion system configuration

AC-equivalent model, battery downstream of the conversion limit. DC voltages, extra conversion losses and DC-side clipping recovery are not modelled. Verify actual equipment compatibility. The AC battery has its own bidirectional converter; the shared limit does not include its discharge.

Photovoltaic system Azimuth (°; North 0, East 90, South 180, West 270) NESW Azimuth

Tilt (°) · Azimuth

Historical PVGIS-ERA5 and wind series are matched by UTC hour in 2008–2017. PV uses an exploratory isotropic model with temperature and clipping; direct normal irradiance is inferred from horizontal beam irradiance, limited near the horizon. This is not TMY.

Estimate limitations

Preliminary estimate with modeled data, not site measurements. Buildings, obstacles, turbulence and within-hour variability are not explicitly modeled.

Copernicus Climate Change Service (C3S) · ERA5 (2008–2017) · Global Wind Atlas 4.0 (DTU / World Bank / ESMAP) · Natural Earth.